TRENDING:

Advanced LC meter

LCM3(2)

 

This project is an advanced LCR meter based on PIC16F690 microcontroller.

Description

After finishing my last project – “Simple LC meter“, there were some discussions in the forum I am a member of, that ability to measure electrolytic capacitors would be very useful in this type of device.

I searched the Web and found a very nice project named LCM3 on this Hungarian site: hobbielektronika.hu . I love Hungarian rock since my school days, but I don’t know a word in Hungarian 🙁 . So, I searched the Web again, this time for this specific project and found a Russian forum where the project was discussed in details and I got more useful information about parts, settings and so on.

Specifications of the LCM3 are (according to authors of the project):

  • Capacitors: from 1pF to 1nF – resolution: 0.1pF, accuracy: 1% – from 1nF to 100nF – resolution: 1pF, accuracy: 1% – from 100nF to 1uF – resolution 1nF, accuracy: 2.5%
  • Electrolytic capacitors: from 100nF to 100 000uF – resolution 1nF, accuracy: 5%
  • Inductance:from 10nH to 20H – resolution 10nH, accuracy: 5%
  • Resistance: from 1mOhm to 0.5Ohm – resolution 1mOhm, accuracy: 5%

Download .HEX files here

Schematic

So, I put the schematic in Eagle and this is the result:

LCM3 (schem)

PCB

As usual I designed a new PCB. The PCB is designed in such a way, that it is possible to mount the LCD display on top of the board. The multiturn trimmer for adjusting the contrast is bellow the display, so it must be of this type : Тhere is also an option for mounting a 3-pin terminal connector, so it’s possible to use the whole device without an enclosure.

All resistors are 1% metal film. Two 1nF capacitors are 1% styroflex. CX1 – 33nF is also critical – this must be polypropylene high voltage capacitor. I tried with two types: 10% X2 275Vac and Panasonic 3% 800V – worked fine with both. The inductor must be with low Rdc. There is a connector for a separate adapter, which bypasses the ON/OFF button. Maybe on next revision of PCB I would add an onboard power connector. If the device is powered with external power adapter, you may increase back light current by decreasing the value of the resistor R11. You must consult with the datasheet of the display to select a proper value of the resistor.

Capacitors MUST be discharged before measurement or there is a danger of destroying the chip.

Photos

LCM3(1)

 

LCM3(2)

LCM3(3)

LCM3(4)

LCM3(5)

LCM3(6)

LCM3(7)

LCM3(8)

LCM3(9)

Please follow and like us:
Pin Share

PCB



Subscribe
Notify of
guest

22 Comments
Inline Feedbacks
View all comments
Rick

Do you make the source code available?

Tony

Hello great lc meter but I would like to know the hexadecimal code that you used because there are many starting from v1.22 to v1.30
would you be kind enough to post it thanks greetings

Tony

If it refers to me thank you but I saw that there is also v.1.35
Regards Tony

dominic

can you give me the hex file you used

ravish kumar

Can you provide the program code code of advanced lc meter

Gabriel

What kind of reed relay can i use? this is good EDR101A0500Z 5v , 0,5a

Rich

Very nice meter. Very professional.

gerard

can someone tell me what switch is being used at the lcm3

P

Where is the parts list of this project….?
i need proper parts list.

jean-marc mainvis

Hi,
I made it.and it’s works fine.thank-you.
There is something I don’t anderstand : on the fourth photo ,we can read C m20 = 9.88 µf what is m20 ?
thank you in advance

Rumen

I have problem!How to calibrate the LCM?

Rumen

I resolve my problem!OK!

Roger Albert

Hello,
Very nice project! Would you have the eagle’s files?
Thank you

RELATED PROJECTS

TOP PCB Companies