Everything-that-moves ALARM
author:
Thomas Scarborough
A crucial failing of proximity detectors is their
unreliable and tricky nature. This is where they are used to detect
humans, not to speak of smaller living beings. One common approach
is to detect eddy currents in a living body, which are induced in
the body through a.c. mains wiring. However, such circuits become
altogether unusable in the case of mains failure, or in the absence
of mains electricity, or even where adjacent mains circuits are
switched in and out.

The circuit of Fig.1 takes the guesswork
out of proximity detection by inducing eddy
currents in a living being, whether animal or human.
Five turns of enamelled copper wire (say 30 s.w.g.) are
wound around the area within which detection is to take
place (4m x 4m in tests), and an audio signal of about ¼
Watt is pulsed through this, the Tx, coil. A smaller Rx
coil (say 100 turns of 30 s.w.g. enamelled copper wire
wound on a 150mm dia. former) is used as a pick-up coil.
The circuit is adjusted by means of tune and fine-tune
controls VR1 and VR2, so that it is deactivated when one
stands back from the Rx coil.
A simple clock generator (IC1a-IC1b) and
power MOSFET (TR1) are used for the transmitter, and a
7555 timer (IC2) is wired as a sine-square convertor for
the receiver. IC2's inputs are biased through VR1, VR2
and R4. IC2 in turn switches NAND gates IC1c and IC1d,
to drive relay RLA. Capacitor C5 switches the relay for
about two seconds, and its value may be increased or
decreased to give different timing periods. D2 is
critical to prevent back-e.m.f. from re-triggering the
circuit. Supply decoupling capacitors C1 and C4 are also
critical, and should be located close to IC1 and IC2
respectively.
When a living being - animal or human -
comes within tens of centimetres of the Rx coil, the
circuit is triggered. This coil may be placed in the
threshold of a door, under a carpet, or around a hatch,
at the base of a tree, and so on. A number of such coils
may also be wired in series.
Coils may be wound with a larger or
smaller diameter, with more or less turns, and the power
of the transmitter may be varied, as well as the
sensitivity of the receiver. Note that a.m. radio
reception may be affected at close proximity to the Tx
coil.
 |
|